During food and beverage production, ozone is commonly used in process water treatment, equipment and piping disinfection, and production environment hygiene control. After ozone contacts water or the target being treated, some unreacted ozone may escape as a gas and must be handled through dedicated collection piping and an exhaust-gas treatment device. For this type of gas-phase ozone off-gas, an ozone decomposition catalyst can be used to build a catalytic purification unit so that ozone is decomposed into oxygen under the action of the catalyst. In actual engineering practice, treatment performance depends not only on the catalyst itself but also on ozone generation rate, off-gas flow rate, inlet concentration, gas humidity, pretreatment method, and reactor structure. Design must therefore be based on actual exhaust parameters rather than the nameplate output of the ozone generator.
In the food and beverage industry, ozone mainly participates in disinfection and treatment in gas-phase form or dissolved in water. Off-gas characteristics differ by application method, and the collection and treatment scheme must be determined according to the specific production process.
In process water treatment for food and beverage production, ozone enters water through gas-liquid mixing equipment for water quality treatment and microbiological control. Because gas-liquid mass transfer cannot achieve complete transfer under all operating conditions, some undissolved ozone escapes with gas from contact tanks, mixing equipment, or other vent locations. The ozone concentration in this type of off-gas is jointly affected by gas-liquid contact efficiency, water temperature, contact time, and ozone consumption in water. It is typically on the order of tens to hundreds of mg/m³, and the actual value should be based on measurements at the vent location.
During engineering design, gas collection connections must be provided according to the structure of the gas-liquid contact equipment, the off-gas discharge location, and the operating mode, and the undissolved ozone gas must be routed to the downstream treatment device. Contact-tank level fluctuations, foam carryover, and condensate accumulation in piping can all change the resistance characteristics of the off-gas system, thereby affecting the fan operating point and the stable operation of the decomposition unit.
Some food and beverage production lines use ozone to disinfect water storage facilities, transfer piping, production equipment, and related contact surfaces. During disinfection, ozone may enter the internal space of equipment or the piping system in gas form. Off-gas from closed-equipment disinfection has a clear intermittent, concentrated discharge pattern: the disinfection stage may last from tens of minutes to several hours, and discharge is concentrated in the purge stage after disinfection ends, with both flow rate and concentration in the short term potentially higher than those of continuous discharge conditions.
After disinfection, equipment exhaust, purging, and residual ozone treatment must be included in the process design. The location of exhaust outlets, discharge cycle, and duration of a single discharge should be clearly defined, and the throughput capacity of the treatment device under peak flow must be checked accordingly to avoid short-term overload of the catalyst bed or sudden pressure-drop surges caused by intermittent concentrated discharge.
Some production sites may use gaseous ozone for space disinfection or specific environmental treatment. This type of off-gas exists directly in the treated space, and its collection method is fundamentally different from that for ozonated water production: ozonated water off-gas can be led out from the vent of contact equipment through closed piping, whereas space-disinfection off-gas usually requires mechanical exhaust after disinfection to displace indoor ozone-containing air, which is then sent to a decomposition device or discharged after dilution by exhaust air.
For space disinfection scenarios, the operating procedure should incorporate the off-gas treatment step. A typical sequence is: close off and partition the area, confirm clearance, start disinfection, decompose off-gas, exhaust and attenuate, and allow personnel to enter only after testing confirms compliance. The off-gas treatment scheme for ozonated water production cannot simply be applied to space disinfection scenarios, nor can an off-gas decomposition device replace overall workshop ventilation and personnel isolation management.
Catalytic decomposition of ozone off-gas is not accomplished simply by installing a catalyst in an exhaust duct; it requires a relatively complete gas collection and purification system. It usually includes the following functional units.
Off-gas collection is the starting point of the entire treatment system. For ozonated water production equipment, collection connections should be provided according to the locations of the gas-liquid contact tank, mixing device, and vents; for gaseous ozone equipment disinfection processes, the collection method must be determined according to the internal exhaust path and purge method of the equipment. The collection system should preferably operate under slight negative pressure, typically on the order of tens to hundreds of pascals. This is sufficient to prevent ozone from escaping into the work area without introducing excessive ambient air that would dilute the ozone concentration and increase the downstream treatment flow rate.
Closed piping should be used for transport during design to reduce fugitive ozone emissions during collection. At the same time, the discharge timing and operating cycles of different equipment should be considered to avoid insufficient collection capacity when multiple discharge points operate simultaneously. For intermittent discharge conditions, the collection piping and fan selection flow rate should be checked against peak exhaust flow rather than selected based on average flow.
Collected ozone off-gas must be transported to the catalytic decomposition device through piping. Fan configuration should comprehensively consider actual gas flow rate, piping length, number of elbows, equipment resistance, and system operating mode. Piping materials should withstand the strong oxidizing nature of ozone; elastomeric seals that are easily aged by ozone and ordinary carbon steel inner walls should be avoided.
During food and beverage production, some ozone off-gas may carry water mist, droplets, or other impurities. If these substances enter the catalyst bed directly, they may wet the catalyst surface, block pores, or change the gas flow distribution. Water molecules and ozone molecules compete for adsorption on catalyst active sites, which is one of the main factors causing deactivation of transition metal oxide catalysts. For conditions with obvious droplet or water mist carryover, a gas-liquid separator or demister should be installed ahead of the reactor. When the off-gas relative humidity is high, preheating the gas to 50–60 °C before it enters the catalyst bed may be considered to suppress moisture accumulation on the catalyst surface. The specific form of pretreatment equipment must be determined according to the actual gas liquid content and temperature/humidity; the off-gas from all food and beverage production lines cannot be regarded as the same operating condition.
The catalytic decomposition unit is the core of the system. Its main structure includes the reactor, ozone decomposition catalyst, and necessary support and sealing components. The core parameters of reactor design are space velocity and gas residence time. Space velocity indicates the gas volume passing through a unit volume of catalyst per unit time, while residence time is the actual contact time of the gas in the catalyst bed. The two are reciprocals (when expressed as volume space velocity, residence time ≈ 1/space velocity, corrected for temperature and pressure). For ambient-temperature ozone decomposition catalysts, common engineering reference values for volume space velocity are 10,000–80,000 h⁻¹, corresponding to a gas residence time of approximately 0.08–0.36 s. The specific value depends on catalyst activity, inlet concentration, and allowable outlet concentration. The gas velocity inside the reactor should be controlled within a reasonable range (for example, honeycomb catalysts are generally recommended not to exceed about 3 m/s) to avoid insufficient residence time and excessive bed pressure drop caused by excessively high velocity.
The reactor structure must match the catalyst form. For granular catalyst packed beds, attention must be paid to particle size, bed height, support layer structure, and gas distribution. Although a smaller particle size can increase specific surface area, it significantly increases pressure drop. For honeycomb catalyst modules, attention must be paid to channel size, inter-module sealing, and gas flow uniformity to prevent gas from short-circuiting through module edges. Regardless of the form used, the gas should be ensured to pass uniformly through the effective catalyst reaction area to reduce short-circuit flow and local excessive flow. The reactor should also be provided with pressure-differential monitoring ports to track long-term changes in bed pressure drop.
Gas after catalytic decomposition is discharged through exhaust piping. To verify system performance, ozone concentration sampling points should be installed at the catalytic reactor inlet and outlet. For online monitoring, UV absorption is preferred, using the characteristic absorption of ozone at 254 nm for continuous measurement. For periodic comparison or acceptance testing, the iodometric method may be used; the iodometric method is the arbitration method for ozone concentration determination. Online UV analyzers should be calibrated periodically by the iodometric method to ensure data reliability.
For continuously operating production lines, monitoring and interlock measures linked to the ozone generation system should also be provided. When the ozone concentration at the exhaust outlet exceeds the set control value, the fan fails and stops, the catalytic bed pressure differential rises abnormally, or the decomposition unit temperature becomes uncontrolled, the system should automatically alarm and interlock to shut down the ozone generator to prevent untreated ozone from continuing to be discharged.
Ozone decomposition is essentially the conversion of ozone into oxygen. Under the action of a catalyst, ozone molecules are adsorbed and activated on the catalyst surface and complete decomposition through surface reactions. The catalyst provides active sites favorable for the reaction and lowers the kinetic barrier. The catalyst itself is not continuously consumed during the reaction. The actual performance of the catalyst must be comprehensively evaluated in combination with material activity, surface structure, gas contact conditions, and operating environment.
Ozone inlet concentration and off-gas flow rate jointly determine the ozone mass rate entering the catalyst bed and are the basic parameters for evaluating catalyst treatment load. When concentration or flow rate changes, both ozone load and gas residence time change simultaneously. Catalyst specifications cannot be estimated solely from the rated output of the ozone generator; instead, the product of actual flow rate and ozone concentration entering the treatment device should be used as the basis for load verification. For conditions with obvious concentration fluctuations, catalyst loading and reactor cross-sectional area should be checked against the highest possible load.
The effect of water vapor on ozone decomposition catalysts varies by catalyst system. For many transition metal oxide catalysts, water molecules and ozone compete for adsorption on active sites, which can reduce catalytic activity. Some modified catalysts can still maintain good stability at high humidity; for example, certain cerium-nickel composite oxides can maintain ozone conversion above 94% at 90% relative humidity. The basic engineering strategy for addressing humidity is to first reduce the free water content entering the reactor through gas-liquid separation and demisting. For high-humidity off-gas that cannot be avoided, the inlet gas temperature may be appropriately increased (for example, to 50–60 °C) to reduce relative humidity, or a catalyst model designed for humidity resistance may be selected. If catalyst activity decreases due to accumulated moisture adsorption, some products can be regenerated by drying at about 80 °C and then recover activity, but regeneration conditions and the number of regeneration cycles should be based on the catalyst supplier's technical documents.
Granular catalysts are suitable for packed-bed reactors and require attention to particle size, loading height, bed support, and gas distribution. Honeycomb catalysts have regular channels and are suitable for modular reactor designs, with key attention to channel size, module installation sealing, and gas flow uniformity. The two forms each have applicable conditions, and treatment capacity cannot be judged solely by appearance or loading method. One practical advantage of honeycomb catalysts is that they can maintain relatively low pressure drop at higher space velocities, but once their channels are blocked by dust or droplets, cleaning and replacement are less convenient than with bulk granular material. Selection should comprehensively consider treatment flow rate, allowable pressure drop, gas cleanliness, and maintenance conditions.
The treatment flow rate should be based on measured or process-calculated off-gas exhaust volume, not the rated output of the ozone generator. For ozonated water production systems, off-gas flow mainly depends on the amount of undissolved gas discharged and the exhaust method of the contact equipment. For intermittent disinfection exhaust, the design flow rate should be determined according to peak exhaust flow and duration, with consideration of time overlap among multiple discharge points. A certain margin should be allowed in the design flow rate, but an excessive margin will lead to overly low actual operating space velocity and increased energy consumption, while an insufficient margin cannot cover peak conditions.
Inlet ozone concentration is the direct basis for calculating catalyst load. Before engineering design, the inlet concentration should be measured under representative operating conditions, or estimated by mass balance based on gas-liquid contact efficiency, with consideration of the concentration fluctuation range under different production processes, disinfection cycles, and operating states. Catalyst loading and reactor cross-sectional area should be checked according to the ozone mass rate corresponding to "design flow rate × maximum inlet concentration" to ensure sufficient catalytic decomposition capacity under the most unfavorable conditions.
Food and beverage production lines usually need to balance equipment layout, piping connections, space utilization, and routine maintenance. The size and structure of the reactor should match the actual installation space. For granular catalyst beds, space should be reserved for loading, unloading, and sampling. For honeycomb catalyst modules, the modules should be removable from the side or top of the reactor for replacement. Regardless of the form, reducers and elbow arrangements at the reactor inlet and outlet should be designed so that the gas flow is distributed as uniformly as possible before reaching the catalyst cross-section, avoiding local catalyst overload or short-circuiting caused by local high-speed gas flow.
If the ozone off-gas contains significant water mist, droplets, or particulate matter, pretreatment should be configured before the gas enters the catalyst bed. The selection of gas-liquid separators and demisters should be based on gas liquid content, droplet size distribution, and allowable pressure drop. For conditions with large temperature and humidity variations, attention should be paid to the risk of condensation inside piping and equipment, and insulation or heat tracing measures should be taken for pipe sections when necessary. The installation of pretreatment equipment should not significantly increase the total system pressure drop; otherwise, the fan head must be increased accordingly or the reactor flow area adjusted.
The system should have representative sampling points at the catalytic reactor inlet and outlet. Sampling point locations should avoid elbows, reducers, and local eddy zones. The inlet sampling point should be located after pretreatment and before the catalyst, and the outlet sampling point should be located after the catalyst bed and before the discharge outlet. Online UV absorption is suitable for continuous monitoring and trend tracking; the iodometric method or an instrument method calibrated by the iodometric method is suitable for acceptance testing and periodic comparison. Gas flow rate, temperature, and humidity should be recorded during testing because these conditions directly affect concentration readings and catalytic reaction performance.
When the inlet concentration is not zero and the test conditions are comparable, decomposition efficiency is calculated as follows:
Ozone decomposition efficiency = (inlet ozone concentration − outlet ozone concentration) ÷ inlet ozone concentration × 100%
Decomposition efficiency and outlet concentration are two different evaluation indicators. High efficiency does not necessarily mean that the outlet concentration meets the requirements. When the inlet concentration is high, even if efficiency reaches 95% or more, the outlet concentration may still exceed the control value. Engineering acceptance should use whether the outlet concentration meets the applicable emission or occupational hygiene limits as the core criterion, while using efficiency data to assist in judging the operating status of the catalyst bed. Regarding occupational exposure limits, GBZ 2.1—2019 specifies an ozone PC-TWA of 0.3 mg/m³ and a PC-STEL of 0.5 mg/m³. Ozone concentrations in workplace air and near the off-gas discharge outlet should be controlled with reference to these limits; the discharge outlet should also meet the specific limits required by the project EIA approval or local emission standards.
Initial acceptance data represent performance only under specific operating conditions. During long-term operation, inlet and outlet ozone concentrations, catalyst bed pressure differential, system flow rate, and gas temperature should be recorded periodically. A continuous increase in pressure differential usually indicates dust accumulation in the bed, catalyst pulverization, or blockage of gas flow channels; a sudden decrease in pressure differential may indicate catalyst layer collapse, bypass leakage, or seal failure. A gradual increase in outlet concentration without significant changes in inlet concentration and flow rate may be a signal of catalyst activity decay. For food and beverage production lines, attention should also be paid to the effects of cleaning, shutdown, and restart stages on the system: condensate may accumulate in piping during shutdown, and before restart the system should first be purged with ventilation and checked for pressure differential and dew point before the ozone generation equipment is put into operation.
Ozone off-gas treatment for food and beverage production lines requires a treatment system matched to the specific ozone use stage and exhaust characteristics. Off-gas generated by ozonated water production, equipment disinfection, and space disinfection differs in collection method, flow characteristics, and concentration level, and should be analyzed separately. Effective treatment should be achieved through closed collection, reasonable transport, necessary pretreatment, and catalytic decomposition. The basic design basis is measured or calculated off-gas flow rate, inlet ozone concentration, and temperature/humidity conditions, not the rated parameters of the ozone generator. The ozone decomposition catalyst is the core material of the purification system, but its actual performance depends on the matching among the catalyst, space velocity, humidity, reactor structure, and pretreatment, and must be verified through outlet concentration testing and long-term operating data. Minstrong ozone decomposition catalyst can be used as one material option for related gas-phase ozone off-gas treatment projects. The specific product form, loading scheme, and operating conditions should be engineering-evaluated in combination with inlet concentration, treatment flow rate, temperature and humidity, and equipment structure.
Contact: Candyly
Phone: +8618142685208
Tel: 0086-0731-84115166
Email: sales@minstrong.com
Add: E2 Building, Kinglory Science And Technology Industrial Park, Wangcheng Area, Changsha, Hunan, China.