Industrial ozone off-gas catalytic decomposition performance often deviates significantly from laboratory ideal-condition test data. The core reason is that industrial operating conditions are far more complex than laboratory settings—in high-humidity environments, water molecules compete with ozone molecules for active sites on the catalyst surface. When relative humidity exceeds 60%, the decomposition efficiency of conventional catalysts begins to decline rapidly; above 80%, activity can drop to below 30% of its initial value within hours. Under intermittent operation, frequent start‑stop cycles cause thermal shock and accumulation of surface adsorbates, further accelerating structural degradation and performance loss. Studies indicate that catalysts not specifically designed for such conditions can have their service life shortened to only 20%–30% of what they would achieve in normal industrial off‑gas environments in high‑humidity, sulfur‑containing applications such as wastewater treatment plants. Addressing these two major wide‑operating‑condition challenges requires both multi‑component synergy or hydrophobic modification at the catalyst material level, and system‑level design adaptation—only then can long‑term, stable operation of ozone off‑gas treatment systems be ensured.

1. Introduction: The Need for Ozone Off‑Gas Abatement in Industrial Applications

Ozone (O₃), as a strong oxidant, is widely used in water treatment, electronics manufacturing, printing and packaging, medical and healthcare, and industrial exhaust gas treatment. However, ozone is also a potent irritant that can damage the human respiratory tract and corrode certain equipment materials. During ozone use, residual unconsumed ozone is discharged as off‑gas; if released untreated directly into the environment, it causes secondary pollution.

Currently, two main technological routes exist for industrial ozone off‑gas treatment: thermal decomposition and catalytic decomposition. Thermal decomposition requires heating to high temperatures, consuming significant energy and demanding large capital investment. Catalytic decomposition, by contrast, uses a catalyst to lower the activation energy of the ozone decomposition reaction, enabling rapid conversion to oxygen at ambient temperatures without additional heating—widely recognized as the most effective low‑temperature ozone abatement method.

However, actual industrial conditions are extremely variable—ozone concentrations can fluctuate widely from low to high, gas flow rates change frequently, temperature and humidity conditions vary, and off‑gas may carry particulates, volatile organic compounds (VOCs), sulfides, and other interfering components. Among these, high humidity and intermittent operation are the two most challenging factors that directly determine whether a catalyst can maintain long‑term stable performance in field applications.

2. High‑Humidity Conditions: The Primary Hurdle for Ozone Decomposition Catalysts

2.1 Why Does Humidity Inhibit Catalytic Activity?

The core of ozone catalytic decomposition lies in the active sites on the catalyst surface—typically defect sites, oxygen vacancies, and metal ion active centers on metal oxide surfaces. Under dry conditions, ozone molecules can rapidly diffuse to the catalyst surface and adsorb onto active sites, followed by electron transfer and oxygen‑species transformation, ultimately decomposing to oxygen.

But when humidity rises, water molecules compete with ozone molecules for adsorption on active sites. Water molecules generally have higher adsorption energy on manganese‑based active sites than ozone, thus preferentially occupying oxygen vacancies. Experimental data show that Ti‑modified Mn‑based catalysts achieve nearly 100% ozone conversion at 50% relative humidity, dropping to about 95% at 70% RH and still maintaining about 54% performance at 90% RH. When relative humidity exceeds 80%, the activity of some catalysts can fall below 30% of initial values within hours.

The underlying mechanism of high‑humidity deactivation is: water molecules, upon entering the catalyst system, form hydroxyl groups (—OH) on the surface, altering surface oxygen species ratios. When water coverage becomes too high, it hinders oxygen‑species migration, slowing the catalytic cycle. Moreover, during ozone decomposition, peroxide species (O₂²⁻) continuously form and stably adsorb onto oxygen vacancies, blocking active sites and remaining difficult to desorb even after stopping ozone flow. In industrial settings, performance measured under dry laboratory air does not fully represent real‑world performance. In applications such as water treatment, industrial oxidation, and off‑gas treatment, relative humidity often remains above 50% for extended periods, and in some cases approaches saturation.

2.2 Limitations of Single‑Component Catalysts

Manganese dioxide (MnO₂), as the most common ozone decomposition catalyst, performs well under dry conditions. However, in high‑humidity environments, it rapidly deactivates due to competitive water adsorption and accumulation of intermediate oxygen species. Studies show that a catalyst loaded only with manganese oxide achieves 99.1% ozone decomposition within 4 hours under dry conditions, but this drops to 64.2% at 80% relative humidity. Such performance degradation is especially pronounced under high humidity, limiting the engineering application of single‑component manganese‑based catalysts over a wide humidity range.

3. Intermittent Operation: Hidden Losses from Frequent Start‑Stop Cycles

3.1 Which Industrial Scenarios Involve Intermittent Operation?

In practice, ozone‑generating equipment does not always run 24/7. The following scenarios typically involve intermittent operation:

  • Corona treatment and printing industry: corona treatment equipment for plastic films and printing/packaging frequently starts and stops according to production schedules, subjecting catalysts to repeated thermal cycles from ambient to operating temperature and back.
  • Medical and healthcare disinfection equipment: disinfection cycles are discontinuous, with equipment running intermittently.
  • Water treatment systems: some small‑ to medium‑scale water treatment facilities do not operate continuously around the clock.
  • Electronics manufacturing: processes such as wafer cleaning occur in batches, with pulsed ozone supply.

3.2 Damage Mechanisms of Intermittent Operation on Catalysts

Intermittent operation affects catalysts mainly through the following aspects:

Thermal shock. Each shutdown cools the catalyst to room temperature, and upon restart the temperature rises sharply, which can cause micro‑crack propagation in the catalyst structure.

Accumulation of surface adsorbates. During shutdown, ambient water vapor and impurity gases continue to adsorb onto the catalyst surface. Studies show that some catalysts lose activity faster under 50% and 70% RH, but activity can recover after 15 minutes of dry‑gas purging—indicating that adsorbed moisture is partially reversible. However, repeated adsorption‑desorption cycles still cause cumulative structural damage.

Retention of intermediate oxygen species. Shutdown interrupts the catalytic cycle, leaving peroxide‑type intermediates trapped on active sites. These species are difficult to desorb at room temperature and gradually occupy active sites.

Accumulation of irreversible deactivation. The performance loss from each start‑stop cycle is not fully recoverable; after many cycles, the catalyst may need replacement before its expected service life.

3.3 Performance Differences Between Continuous and Intermittent Operation

Comparative data show that optimized composite catalysts exhibit better cyclic durability under intermittent conditions. Studies indicate that some catalysts maintain nearly 100% ozone removal after five reaction cycles. Other research on NiFe‑LDH catalysts demonstrates high activity and long‑term stability over a wide humidity range, offering a reference for real‑world intermittent ozone abatement. These results suggest that through rational material design and regeneration strategies, the performance degradation associated with intermittent operation can be effectively mitigated.

4. Technical Solutions to Wide‑Operating‑Condition Challenges

4.1 Bimetallic / Multi‑Component Synergy Strategies

Copper‑manganese composite catalysts. The introduction of copper is not a simple superposition of two oxides, but rather produces significant synergistic effects through chemical interaction. Cu‑Mn doped oxides synthesized by direct coprecipitation, tested at ambient temperature, 300 L·g⁻¹·h⁻¹ gas hourly space velocity (GHSV), and 85% RH, showed excellent ozone decomposition performance, achieving 98% conversion and stable operation for 10 hours. Characterization indicated that the enhanced water resistance and activity can be attributed to increased active‑site density, larger specific surface area, abundant reactive oxygen species, and lower manganese oxidation state. More importantly, CuMnAl catalysts can be tuned by adjusting aging time to induce a "water‑promoted" reaction pathway on the surface—transforming water from a "poison" into a "promoter." Research shows that reducing the aging time of CuMnAl catalysts preserves more Brønsted acid sites and surface hydroxyl groups, promoting water activation to participate in ozone degradation, achieving 93% ozone conversion at 45°C and 90% RH—12% higher than under dry conditions. This catalyst performs efficiently over a broad range of 0–90% RH and temperatures ≤45°C.

Cerium‑manganese composite oxides. Incorporating cerium into MnO₂ octahedral molecular sieves (OMS‑2) significantly enhances high‑humidity performance. Studies show that CeMn₄ with a Mn/Ce atomic ratio of 4 exhibits the largest specific surface area, smallest particle size, and highest oxygen‑vacancy concentration, achieving stable ozone decomposition above 95% at 90% RH, GHSV 700,000 h⁻¹, and 420 minutes on stream, with strong water resistance. Cerium‑manganese composite oxides are promising as ideal industrial materials for catalytic ozone decomposition.

Activated carbon and CeO₂ dual‑hydrophobic‑protected manganese‑based catalysts. Researchers developed a manganese‑based catalyst with dual hydrophobic protection from activated carbon and CeO₂ (CeMn@AC), which possesses abundant interfacial oxygen vacancies and excellent desorption capability for peroxide intermediates. Under extreme high humidity (90% RH) and high space velocity (1200 L h⁻¹ g⁻¹), the optimized CeMn@AC achieved nearly 100% ozone conversion at 5 ppm ozone and ran stably for 140 hours. In situ diffuse reflectance infrared spectroscopy and theoretical calculations confirmed that the excellent water resistance stems from the dual protection of AC and CeO₂—AC provides a hydrophobic reaction environment, while CeO₂ further alleviates moisture‑induced degradation of exposed MnO₂ particles through the water‑resistant oxygen vacancies at MnO₂–CeO₂ interfaces.

4.2 Hydrophobic Modification and Interface Engineering

External hydrophobic treatment of catalysts can effectively reduce water molecule occupation of active sites, enhancing catalytic performance under high humidity. Researchers developed hydrophobic carbon‑coated mesocrystalline MnO (Meso‑MnO@C), which features high‑density manganese‑vacancy‑based Lewis acid‑base pairs. The hydrophobic carbon layer prevents moisture accumulation on the catalyst surface under wet conditions, achieving nearly 100% ozone decomposition at 65% RH and high GHSV of 1500 L·g⁻¹·h⁻¹, with stable operation for 100 hours. Additionally, modulating interfacial electric fields and active‑site spin states to repel polar water molecules while enhancing ozone adsorption represents a cutting‑edge approach.

4.3 Electric‑Field Assistance and Catalyst Morphology Optimization

Electric‑field‑assisted ozone decomposition (EAOD) mode. Researchers developed a simple, green, and effective EAOD reaction mode by applying a DC electric field to MnO₂/Al monolithic catalysts to enhance water resistance under high humidity. In EAOD mode, the MnO₂/Al catalyst exhibited stable ozone conversion above 82% at 90% RH and maintained excellent stability over 720 minutes. The external electric field induced water evaporation, hindering water‑vapor competition for active sites, thereby improving water resistance.

Catalyst morphology optimization. The choice of catalyst form is also important for different applications. Monolithic α‑MnO₂ catalysts at pH=7 and GHSV 900,000 h⁻¹ achieved 100% and 95% conversion of 18 ppm ozone under 90% RH and dry conditions, respectively. This monolithic catalyst showed remarkable water resistance in alternating humidity‑cycle tests and continuous high‑humidity tests, maintaining 90% ozone decomposition efficiency after 3 hours under high humidity and exceeding 99% conversion over a 50‑hour test period. Honeycomb catalysts, with low pressure drop and ease of loading/unloading, are suitable for low‑concentration, high‑volume ozone streams, and are widely used in printing plants, high‑voltage discharge facilities, corona treatment units, and UV ozone disinfection applications.

5. Typical Industrial Scenario Analysis and Catalyst Selection Recommendations

5.1 Ozone Off‑Gas from Water Treatment

Water treatment is one of the largest markets for ozone applications. Ozone enters the water body through gas‑liquid contact, and the off‑gas leaving the reactor carries substantial water vapor. In wastewater treatment plants, the relative humidity of ozone off‑gas often reaches above 95%, with the presence of sulfur (H₂S 5–50 ppm, sometimes >100 ppm) and ammonia (NH₃ 5–30 ppm). Under such high‑humidity, sulfur‑containing conditions, catalysts not specifically designed can have their service life shortened to 20%–30% of what they would achieve in normal industrial off‑gas environments. A case study from an industrial wastewater ozone treatment project showed that the initial ozone outlet concentration met design requirements, but after several months of operation the outlet concentration gradually increased—inspection revealed no significant mechanical crushing of the catalyst; the primary cause was increased surface adsorbed water and reduced active‑site utilization due to prolonged high‑humidity operation. For such conditions, priority should be given to multi‑component catalysts such as copper‑manganese, cerium‑manganese composites, or catalysts with dual hydrophobic protection, along with consideration of dehumidification pre‑treatment.

5.2 Corona Treatment and Printing Industry

In corona treatment equipment for plastic films and printing/packaging, high‑voltage discharge generates substantial ozone by‑products. These scenarios are characterized by low concentration, high air volume, and in some cases continuous operation. Corona‑specific ozone decomposition catalysts use manganese‑copper composite oxides as active components, with applicable humidity typically required to be below 70%. Under intermittent operation, the manganese‑copper composite shows better cyclic durability than single‑manganese alternatives. Honeycomb ozone decomposition catalysts, with low pressure drop and easy handling, are widely applied in printing plants for high‑volume, low‑concentration ozone abatement.

5.3 Medical and Healthcare Disinfection Equipment

Ozone disinfection is widely used in healthcare due to its advantage that residual ozone decomposes to oxygen without secondary pollution. Such scenarios present dual challenges of high humidity (RH typically >70%) and intermittent operation. Studies show that appropriate doping modification allows catalysts to maintain relatively high ozone conversion at 70% RH. Catalytic decomposition can rapidly convert ozone to oxygen at ambient temperature without additional heating. In medical disinfection devices, catalytic decomposition units are often employed to ensure outlet ozone concentrations fall below safety limits. High‑concentration ozone decomposition generates considerable heat; activated carbon and other temperature‑sensitive materials pose combustion risks, whereas metal oxide catalysts offer better thermal stability.

5.4 Electronics Manufacturing and Semiconductors

In semiconductor manufacturing, ozone is widely used in wafer cleaning and photoresist removal. The electronics and semiconductor industry imposes strict requirements on ozone off‑gas treatment, including tight control over particulates and ionic leaching in cleanroom environments. Catalytic decomposition operates at ambient temperature, converting ozone to oxygen without introducing additional heat or contaminants, making it highly suitable for cleanrooms. Some equipment already incorporates built‑in ozone catalyst units to reduce exhaust ozone concentrations to safe levels.

5.5 Industrial Air Purification and Synergistic VOC Abatement

In industrial air purification, ozone is not only a pollutant to be removed but can also work synergistically with catalysts for low‑temperature catalytic oxidation of VOCs. Bimetallic catalysts such as manganese‑copper and manganese‑cerium show good performance in ozone‑assisted catalytic oxidation of VOCs. This "waste‑treats‑waste" approach—using residual ozone in off‑gas to simultaneously treat VOCs—offers a new technological pathway for industrial exhaust treatment.

6. Key Selection Criteria and Maintenance Strategies in Engineering Practice

6.1 Core Considerations for Catalyst Selection

Selecting an ozone decomposition catalyst under wide‑operating‑condition scenarios requires comprehensive evaluation of the following factors:

Humidity is the primary screening criterion. Relative humidity of 60% is a critical inflection point for ozone decomposition catalyst performance. If RH consistently stays below 40%, an economical manganese dioxide catalyst may suffice; for RH between 40% and 70%, a copper‑manganese composite catalyst is recommended; for RH exceeding 70% or even reaching above 90%, a water‑resistant catalyst (e.g., cerium‑manganese, copper‑manganese‑aluminum, or dual‑hydrophobic‑protected formulations) is mandatory.

Operation mode determines life expectancy. For continuous operation, long‑term stability is key; for intermittent operation, thermal‑shock tolerance and cyclic durability are more important.

Concentration and space velocity. High‑concentration, high‑space‑velocity applications require more active catalyst systems. Some catalysts maintain over 95% decomposition at space velocities as high as 700,000 h⁻¹.

6.2 System Design Optimization Recommendations

Pre‑treatment. For high‑humidity conditions, consider installing dehumidification pre‑treatment (e.g., gas‑liquid separators, condensate dehumidifiers) to bring RH within a suitable range. Dust‑laden off‑gas should first pass through particulate filtration to prevent particle coverage of active sites.

Catalyst form selection. Pellet‑type catalysts suit medium‑to‑high concentration and small‑to‑medium flow rates; honeycomb catalysts, with low pressure drop and easy handling, are better for low‑concentration, high‑volume industrial air purification.

Operating parameter control. Maintain appropriate temperature and humidity ranges, optimize flow distribution and space velocity, and establish regular maintenance protocols. Implement pressure‑drop monitoring to promptly detect bed plugging or crushing. For intermittent operation, consider insulation or standby modes to reduce thermal‑shock frequency.

Regeneration strategy. When catalyst performance declines, dry‑gas purging may restore activity. Studies show that some catalysts lose activity under wet conditions but recover after brief dry‑gas purging.

6.3 Economic Analysis

From a full‑life‑cycle perspective, although multi‑component catalysts such as copper‑manganese and cerium‑manganese composites have higher initial procurement costs than single manganese dioxide, their extended service life and reduced maintenance requirements under wide‑operating‑condition environments make the total cost of ownership more favorable. Practice shows that controlling suitable operating conditions, reducing poisoning risks, and optimizing flow distribution and space velocity are often more effective in improving ozone removal efficiency and extending catalyst life than simply increasing catalyst loading. Especially in complex conditions involving high humidity and intermittent operation, the cumulative cost of frequent replacement of single‑manganese catalysts far exceeds the one‑time investment in high‑performance composite catalysts.

7. Conclusion

Catalytic decomposition of ozone off‑gas is a critical step in ensuring the safety and environmental compliance of industrial ozone applications. Actual industrial operating conditions are complex and variable—humidity, temperature, concentration, and operation mode all impose differentiated demands on catalyst performance. Single‑component manganese dioxide can meet basic needs under dry, continuous, stable conditions, but under complex scenarios such as high humidity and intermittent operation, its performance declines rapidly, making it unsuitable for long‑term engineering service.

The technological pathways to meet wide‑operating‑condition challenges are increasingly clear. Copper‑manganese composite catalysts, through bimetallic synergy, achieve efficient ozone abatement across 0–90% RH; cerium‑manganese composite oxides maintain >95% stable decomposition at 90% RH and high space velocity; manganese‑based catalysts with dual hydrophobic protection from activated carbon and CeO₂ achieve nearly 100% ozone conversion at 90% RH and run stably for 140 hours. Hydrophobic modification, interface engineering, electric‑field assistance, and morphology optimization further expand the operating envelope of these catalysts.

In engineering practice, selection should be based on specific site conditions—humidity, temperature, operating mode, etc.—with 60% RH as a key inflection point; high‑humidity conditions call for water‑resistant multi‑component catalysts. Rational pre‑treatment and system integration, combined with well‑defined operation, maintenance, and regeneration protocols, are essential to achieve long‑term stable operation and optimal total cost of ownership for the catalytic decomposition system.

CATEGORIES

    CONTACT US

    Contact: Candyly

    Phone: +8618142685208

    Tel: 0086-0731-84115166

    Email: sales@minstrong.com

    Add: E2 Building, Kinglory Science And Technology Industrial Park, Wangcheng Area, Changsha, Hunan, China.